Loading...
If you're writing a spec, pricing a tender, or scoping a fit-out, work with a flooring contractor that turns up with more than a sample.
Manufacturer data sheets for the system we recommend. Build-up, performance and the standards they reference.
Public liability insurance, WorkCover QLD, system-specific SWMS, H-class dust control.
We look at the slab, quote in writing, agree the finish on a sample and hand over clean.
Send the brief through the form. The documents come with the quote, or on request if you need them sooner.
Real jobs across the Gold Coast and Brisbane. Warehouses, showrooms, workshops and fit-outs.
We’re set up to answer the questions the spec and the site auditor ask. Everything we send references the standard it answers, and it comes with the quote rather than after it.
Build-up layers, performance data and compliance references from the manufacturer for the system we recommend, ready to drop into your specification.
Certificates of currency on request, named to your project or head contractor. All site personnel covered under WorkCover QLD.
System-specific Safe Work Method Statements covering silica, grinding, coating and ventilation. Site-specific amendments on request.
H-class vacuums on the grinders, so silica is captured at the head. Fit-tested respirators for the crew.
We choose the finish to suit the rating in the spec and arrange the pendulum test on completion, then pass the report on.
Where the spec calls for them, low-VOC systems and the manufacturer declarations are available across epoxy, polyurethane and microcement.
These are the references we are most often asked to work to. The test data sits on the manufacturer data sheet for each system. If your project calls for a standard not listed, ask and we’ll tell you honestly which systems suit it.
Where the spec calls for a slip rating, we choose the finish to suit and arrange testing on completion.
Where flooring is specified under the NCC as a fire-rated surface, the manufacturer data sheet carries the critical radiant flux figure.
Systems for Class 2 to 9 buildings chosen against the fire hazard properties the NCC calls for. Group number from the manufacturer data on request.
Food and beverage systems chosen to suit the coving, drainage and hygiene requirements in Food Safety Standard 3.2.3.
Bund linings and containment coatings where AS 1940 applies to stored liquids on the floor plate.
ESD-rated systems where the spec calls for them. Tell us the resistance range the spec needs.
Food-plant systems suited to HB 260 hygienic design, including integral coving, falls to drain and monolithic detailing.
Healthcare systems chosen against the guidelines where the spec references them, with coving and cleaning compatibility.
Tell us the project type, size and the standards the spec calls for. Insurance certificates, SWMS and manufacturer data sheets come with the quote, or on request if you need them sooner. Or email info@totalgrind.com.
Send the drawings or a few photos through the form, or email info@totalgrind.com. We will come and look at the slab before we price it.